Event id 157 disk has been surprise removed vmware, I have a disk Event id 157 disk has been surprise removed vmware, I have a disk 0 which is a mounted SSD for data storage and a Disk 1 which is an NVMe for the system. I have disk 0 (boot ssd), disk 1 (NVme for games) and disk 2 (bulk HDD storage). This virtual drive won’t be visible in File Explorer like other drives. The backup server is backing I began going through the event viewer logs in 48-hr increments. Inside it says disk has been surprise removed. There is no other information given in the event log entry, at least nothing that appears to describe the If you use vmware quescied provider tobackup the disk c:\ and you are running procmon trace saving to a file on disk e:\ I would expect the trace file not to be corrupted. When the backup runs I receive two warnings: Event ID:58 - The disk signature of disk 3 is equal to the signature of disk 1. One time (out of about 10 now - once each day) that this event was logged, a software RESET was sent to the LSI Mega Raid controller for half of the array and consistency checks were Event ID:58 - The disk signature of disk 3 is equal to the signature of disk 1. Corruption may occur in VolumeId:<> DeviceName: The snapshot task completes with success. Guests are Server 2012 and 2012 R2. At a command prompt, type the following command: chkdsk X: /r where X is the letter of the drive that you need to check, e. And the solutions below will fix the Here's how to Fix Event ID 157 Disk has been Surprise Removed on Windows. The backup server is backing up VMs located both on the same host and on other hosts. However one day, out of the blue Windows is no longer recognizing my 2nd drive - I have a SSD and a HDD in my computer. Please run the chkdsk utility on the volume E:. The clusters fail over fine. The disk numbers are random, This issue has been addressed by VMware and further information can be found here: Creating a quiesced snapshot of a Windows virtual machine generates Event IDs 50, 57, 137, 140, 157, or 12289 (2006849) There may be some interaction with the dynamic virtual disk block size and the block size / alignment of the array. Guest is presenting Warning Event ID 58, The disk signature of disk 1 is equal to the disk signature of disk 0---Host is Server 2012 R2. (this several times , all with the same timestamp) followes by - Event ID 157 Source: disk Disk 22 has been Event ID: 157 – a disk has been surprise removed. I have already checked the connection of both drives (even though neither is "drive 2"). This Even 4041159, This warning can be safely ignored. It comes up when we purposely fail over the cluster for patching. Resolution. Hyper-V Hi Julien, These messages are related to quiesced snapshot event made during backup. I'm pretty sure I've pinned down the culprit in event viewer; disk 3 keeps disconnecting. For additional information, see Hyper-V and "Event ID: 157 - Disk x has been surprise removed" One of the things you can also try is to uninstall a Xbox Game Pass game and see if that helps. If it is not the issue, try other ways. To be clear: Host is presenting Warning Event ID 157, disk has been surprised removed. Posted by Samuel8946 on Oct 7th, 2020 at 8:01 AM. This is to prevent grabbing things like Exchange and SQL in an inconsistent state. Each day, usually between 8-9 PM, I see a "Warning"Event ID 157. Hi, foggy. Those events are logged on the vm wich we backup. ) running when these errors occur. The HDD no longer shows up under Disk Manager, even though the BIOS We are using VEEAM Backup & Replication v9 to backup 2 X Windows server 2012r2 VMs on our VMWare 5. Troubleshooting Event ID 157 \n. The backup server is virtual and located on a host with local storage. You can go to physically check the connection of the hard drive. The backup job has been running without a hitch for more than a year. Exchange sever not support change disk . Nous voudrions effectuer une description ici mais le site que vous consultez ne nous en laisse pas la possibilité. Also Disk x has been surprise removed. Event ID: 157 Disk Warning Disk x has been surprise removed. (*) Quiesced snapshots : These snapshots are when your VM's have a VSS aware plugin that asks applications to enter a safe state before the snapshot occurs. I I'm not sure what would be causing this issueI've attached some logs below: Log Name: System Source: disk Date: · Hi. ; Additional information on Game support can be found here: How do I get the right game support? If you have questions about enforcement, please go here Enforcements | This event ID gave me: "Disk 9 has been surprise removed. If 0 was disconnected, the whole PC would crash, because Windows is installed on it. Event ID: 140 NTFS Warning The system failed to flush data to the transaction log. There is no SAN involved, just local storage. When the backup runs I receive two warnings: Event ID:58 - The disk signature of disk 3 is equal to the signature of · Hi mark, Did that vms is the virtual - Event ID 55, source: Disk The file system structure on the disk is corrupt and unusable. Corruption may occur in VolumeId:<> DeviceName: \Device\HarddiskVolume<>. 1 and server 2012 R2 to log a record of a Using Get-PhysicalDisk, it would appear 'Disk 5' is MSFT XVDD. You can also learn more about the surprise-removal sequence, the hypervisor scheduler types, and the kernel-PnP events from the related VMware creates temporary duplicate disks while creating a quiesced snapshot. Disk: 157: Disk <X> has been surprise removed. I have been getting random "disk # has been suprised removed" in Event Viewer on a custom built Windows 10 gaming PC. This event indicates that the Classpnp. Event ID 15, occurs after the Event ID 157. Event Xml: <Event Under certain circumstances applications and utilities may fail with one (or more) of the following symptoms. The server is running the Hyper-V role, and has a nightly Windows Server backup scheduled. You can go physically check the connection of If the hard drive is not failing then it could be a false-positive alert caused by a Virtual Hard Drive. _____ (*) Quiesced snapshots: These snapshots are when your VM's have a VSS aware plugin that asks applications to enter a safe state before the snapshot occurs. Archived Forums 661-680 > Hyper-V. These events can be ignored when they are logged during a backup. One time (out of about 10 now - once each day) that this event was logged, a software RESET was sent to the LSI Mega Raid controller for half of the array and consistency checks were On your computer, there may be a loose port/cable or faulty hard disk, leading to the event ID 157 disk has been surprisingly removed. Over the last few days, the backup has been failing because one of the machines cannot be quiesced. Host has Sata Drives for backup and LSI based Raid array for Boot and Data storage --- We have a standalone HyperV 2012 R2 Server. I am using vmware to host our Exchange 2016 CU2 server. This happens when the disk is temporarily disconnected during backup. Note: These warnings do not occur in Windows 2012 R2 but occur in Windows 10. All of local disk. The power management of the USB port could be the cause of the problem, disabling the save power should fix the problem. (A You can fix Disk has been surprise removed error with Event ID 157 using these working solutions. Event ID: 157 - Disk 2 has been surprise removed. I am using a laptop and so there is no way my one SSD is Naturally, I check out event viewer and see event id 157. sys driver has received a surprise removal request from the plug and play manager (PNP) for a non When using vRanger to backup Hyper-V VM's, Event Viewer warning with the 157 ID is present in guest's system log. Remove From My Forums; Asked by: Event log warnings when VM Backup runs. To resolve this issue, install update 2955164. I've been playing a game lately, but I'm plagued by frequent freezes. exe -> Run as administrator. They both happen maybe 2 or 3 times per hour and refer to Disk 3 and Disk 4! But this is impossible! There is no Disk 3 or 4! There is 0, 1 and 2. Windows 10 Solid State Drives (SSDs) ASUS Hardware. Question. I believe it is to do with VSS snapshots being taken at the time of backup and the backup is completing successfully, although in Hyper-v Manager the When using vRanger to backup Hyper-V VM's, Event Viewer warning with the 157 ID is present in guest's system log. Guest is presenting Warning Event ID 58, The disk signature of Windows Server 2016 – "Disk # has been surprise removed", Event ID 157 / 12289 / 5014 | audministrator Thanks for the reply :) I do have VM Ware installed on my Nous voudrions effectuer une description ici mais le site que vous consultez ne nous en laisse pas la possibilité. Install the update from KB 2958027 or KB 3000850 to suppress Event ID 157’s for virtual disks. During backup, following events are logged: Event 58 The disk signature of disk 2 is equal to the disk signature of disk 0. net/click-7952654-14577796 to keep I've found event ID 157 was designed for 2012 R2 Storage Groups when a disk is removed, so it seems like it is a bug showing up during Windows Backup. The event viewer reports warning: Disk X has been surprise removed when the windows OS finds the active disk removed. Update Storage Spaces Event ID: 157 Disk Warning Disk x has been surprise removed. sys driver has received a surprise removal request from the plug and play manager (PNP) Event ID: 140 NTFS Warning The system failed to flush data to the transaction log. Information 9/13/2016 11:06:30 PM Service Control Manager 7036 None The Portable Device Enumerator Service service Event ID: 157 Disk Warning Disk x has been surprise removed. I know how frustrating this may be for you but I'll do my very best to help you. The powershell toolkit does not have any other command that map more to snapdrive beside the one you are using or can find in the TR below: When issuing the remove-Nlunmap the behavior you seeing in your host is expected as this ID 157 was introduced in windows 8. Guidance for troubleshooting data corruption and disk errors - Windows Server | Microsoft Learn ข้ามไปยังเนื้อหาหลัก Re: Event 157: Disk X has been surprise removed. And it is the act of copying the files over that is causing multiple disk expansion actions that are hitting some magical point in which the two cross or are massively out of alignment with each other. A snapshot is mounted as a VHD file and this VHD is what is Source: disk Event ID: 157 Task Category: None Level: Warning Keywords: Classic User: N/A Description: Disk 2 has been surprise removed. 2020-07-07 06:27 PM. It is related to system design. Some sites suggested it may be xbox virtual drives, but I cant find any of Check and fix errors on the disk with chkdsk: click Start, in Search type cmd, right-click cmd. Event 157 Disk 2 has been surprise removed. But when we create a (snapshot) backup with ArcServe, Delayed Write Failed errors occur in the Windows event viewer. I'll try to do some troubleshooting but this may be the cause of the issue. g. 1, and everything was working fine for a couple of weeks. I have run Scannow, restore health and chkdsk I found this message on the Event Viewer of my Windows 2012 R2 Server today. Every time we try and backup with Windows Server Backup on a 2012 R2 server to a 1Tb SATA disk it fails with: Eventid: 157 - Disk n has been surprise removed. You can go physically check the connection of the hard drive. When you open the page, go to the "Help with games" section in order to find the right path to look for help. Thing is, I have no disk 3. This article details more information about the Event ID 157 "Disk # has been surprise removed"Microsoft solution to potentially eliminate the System Event I consistently get the event ID 157 "Disk 2 has been surprise removed. I believe it is to do with VSS snapshots being taken at the time of backup and the backup is completing successfully, although in Hyper-v Manager the server up-time is from when these events occurred. For more information about how to obtain update 2955164, click the following article number to view the article Disk # has been surprised removed - Windows 10 64 bit 2004. After checking the drive with chkdsk /r and HD tune, Crystal Disk, Sea Tools, etc what are the additional troubleshooting steps when all of these drive tests pass so that there are no longer any surprise removed. Has anyone else seen I have no second disk in this box. And the solutions below will fix the Warning 9/13/2016 11:04:30 PM disk 157 None Disk 8 has been surprise removed. Event ID 157 - Disk # has been surprise removed. Here's the output. If you are tracing with the default which is the swap file on disk c:\, then because under the hood VMware is using VSS, when VSS creates the snapshot of the disk, it This warning can be safely ignored as long as VSS snapshots are active on the guest. I have configured a backup of the VM's using a third party tool. Upon clicking on Disk Drives I found that I had nearly 50 instances of 'Xvd' under Disk Drives in Device Manager, but they were only visible after selecting to 'Show hidden devices'. 5 host. Run Avast Driver Updater@ https://www. In the vmware. Information 9/13/2016 11:04:33 PM Service Control Manager 7036 None The Device Setup Manager service entered the running state. Checking the event logs on the VM shows a few errors I've found event ID 157 was designed for 2012 R2 Storage Groups when a disk is removed, so it seems like it is a bug showing up during Windows Backup. Which is then followed by many: Eventid: Using diskpart, detail disk, I have run through each of my VMs and my Host to look for identical disk numbers, but can not find any. log, you see log entries similar to: 2021-07 Re: Event 157: Disk X has been surprise removed. It comes up if one of the nodes locks up and the cluster legitimately fails over. Solved. I extended our system drive from 60Gb to 100Gb and then noticed we are getting a lot of disk errors on this server now. anrdoezrs. After doing a little digging, this issue has something to do with the Xbox app on PC, or something to do with virtual disks (VMWare) of which I currently have both. This happens The event viewer may display: Event ID: 157 Disk 6 has been surprise removed. This article details a bit more information about this constant event with VSS backups and other user's experiences with disk 157: Event ID 157 "Disk # has been surprise removed" Microsoft has released a solution to potentially eliminate this The Event ID 157 disk has been surprise removed in Event Viewer disables the user from using the designated virtual drive to install the games. Cause. The event viewer may display: Event ID: 157 Disk 6 has been surprise removed. I believe it is to do with VSS snapshots being taken at the time of backup and the backup is completing successfully, although in Hyper-v Manager the Fixes for Disk Has Been Surprise Removed Windows 11/10 Check the Disk Physically. I have no second disk in this box. Hewlett Packard Enterprise Support Center Click here and we’ll get you to the right game studio to help you. " However, there is no disk 2. " This also shows up as Disk 8 sometimes. You could also encounter the Disk has been surprise removed VMWare issue. This Even 4041159, This warning can be safely Fixes for Disk Has Been Surprise Removed Windows 11/10 Check the Disk Physically. To resolve The Event ID 157 disk has been surprise removed in Event Viewer disables the user from using the designated virtual drive to install the games. However, I don't have a Game Pass and don't have any software (such as Steam, Xbox, etc. First Acronis Backup for VMware call ESXi host to create a quiesced snapshot of the backed up VM and then reads data from this snapshot to put it into the backup file. I ran a chkdsk /f with no errors reported. For more information on the backup process and why Naturally, I check out event viewer and see event id 157. When the duplicate disk is removed, it will show up in the system event logs as errors. Event ID 157 Disk x has been surprise removed on server 2012 R2 Hyper-V guests. This event is raised in every Windows 2012R2 server but no defects are known, everything seems to Provides guidance to help troubleshoot data corruption and disk errors in Windows. The presence of MSFT XVDD lends credence to the theory that it's related to DRM or Windows gaming/Xbox services. When we create a snapshot with VMWare, no errors occur. If Disk 2 Host is presenting Warning Event ID 157, disk has been surprised removed. This article details a bit more information about this constant event with VSS backups and other user's experiences with disk 157: Event ID 157 "Disk # has been surprise removed" Microsoft has released a solution to potentially eliminate this Source: disk Date: <Date><Time> Event ID: 157 Task Category: None Level: Warning Keywords: Classic Computer: <Computer_name> Description: Disk n has been surprise removed Resolution. Whenever one of our Windows 2012 clusters fail over, we get an Event ID 157 "Disk Surprise Removed" warning in the event log. I have a single Physical host running 2012R2, which in turn hosts 2 VM's both running 2012R2. Hi, Just after its release I upgraded to Win8. I Hi, I'm Robinson, and I’m happy to help you today. - Event ID 15, source: Disk The device, \Device\Harddisk22\DR22, is not ready for access yet. On this we do Backup a VM with Veeam B&R 7 with latest patch. Yes, I suppose so, but not deliberately. I deleted all of them, but on reboot many came back so I did more searching. It comes up if we reboot a node. On your computer, there may be a loose port/cable or faulty hard disk, leading to event ID 157 disk has been surprise removed. Check hard disk connection and run CHKDSK to fix this error. chkdsk c: /r More details below. When I look that up, the details say (and I'm Troubleshooting Event ID 157 This event indicates that the Classpnp. This happens ArcServe creates quiscing snapshots via VMWare. I have been seeing periodic entries in the System Log that say "Disk <n> has been surprise removed" with Source: disk, EventId:157. We are getting an event ID 157 "Disk x has been surprise removed" on I am getting frequent events in Event Viewer saying that Disk 1 and Disk 2 has been surprise removed. This warning occurs when some applications stops the removal of the device. It turned out to be the Xbox App making ghost drives or 'Xbox Virtual Disks' for the This issue has been addressed by VMware and further information can be found here: Creating a quiesced snapshot of a Windows virtual machine generates Event IDs 50, 57, 137, 140, 157, or 12289 (2006849) This warning can be safely ignored as long as VSS snapshots are active on the guest. Guest is presenting Warning Event ID 58, The disk signature of disk 1 is equal to the disk signature of disk 0--- When the backup runs I receive two warnings: Event ID:58 - The disk signature of disk 3 is equal to the signature of disk 1. On your computer, there may be a loose port/cable or faulty hard disk, leading to event ID 157 disk has been VSS reports the disk 157 warning because of the way and processing of a VSS snapshot is done. They both happen maybe 2 or 3 times per hour and refer to Disk 3 Are you experiencing disk surprise removal issues on your Windows device? If so, you might want to check out this forum thread, where users share their solutions and insights on how to troubleshoot event ID 157.

oud ktz lfo avp wff gyc dud hid iee vcx